Hall Pyke

The SMART choice for filtration

  • Home
  • Products
    • Col 1
      • Backwashing and self-cleaning filters
      • Capsule Filtration
      • Compressed Air Filters
      • Depth Pre Filtration
      • Dust Filter Cartridges
      • Technical Fabric Filters
    • Col 2
      • Filter Housings
      • High Flow
      • HVAC
      • Hygienic Strainers
      • Liquid Bag Filtration
      • Membrane Filtration
    • Col 3
      • Stainless Steel Filters
      • Stainless Steel Mesh Fabrication
      • Steam Filtration
      • Surface Pre Filtration
      • Water Treatment
  • Services
    • Lab Support Services
    • Filter Integrity Test
    • Filterability Testing
    • Filter Validation
    • Customer Support
    • Leak Detection Test for Baghouses
  • Downloads
    • Hall Pyke Publications
    • Company Downloads
    • How-Tos
  • News
  • Why Us
  • Gallery
  • Contact Us
Home / Products / Surface Pre Filtration / GlassGas

GlassGas

GlassGas

GlassGas Filter Cartridges

Glass Fiber  ·  Pre-filter for Gas

GlassGas Filter Cartridges are composed of super-fine glass microfiber with a dirt holding capacity over 90%. They are highly recommended for the pre-filtration of foul gases as an effective protection for the final sterilizing-grade filters to increase their service life.

Features and Benefits

  • High porosity and flow rates
  • High absorption and retention efficiency
  • Low pressure drops

Quality Standards

  • Designed, developed and manufactured in compliance with ISO9001
  • Full Regulatory Compliance with the following:
    • 21CFR.210.3(b)(5)(6), 211.72 for Non-Fiber Release
    • Endotoxins: <0.25EU/ml/10inch filter
    • USP <88> Plastic Class VI-121°C
    • FDA 21 CFR177-182 & EU 1935/2004/EC

Typical Applications

  • Antibiotic Fermented Air
  • Compressed Air
  • Bio-engineered Fermented Air
Categories / Industries:
Products, Surface Pre Filtration


Details

Email Us Call Us
  • Description
  • Downloads

Description

Flow Rate Characteristics

Materials of Construction

Filter Media Super-fine Glass Microfiber
Support Polypropylene
Core/Cage/End Caps Polypropylene

Operating Conditions

Max. Temperature 80°C
Max. Differential Pressure 4.0 bar / 21°C
  2.4 bar / 80 °C
Effective Filtration Area 0.35 mÇ / ϕ 69-10inch

Sterilization

Inline Steam Sterilization up to 30 cycles (135°C for 30min@30kPa per cycle)

Ordering Information

Removal Ratings End Cap Nominal Length Seal Material
0001=0.01 μm HSF=226 /Fin (PBT Insert) 05=5″ S=Silicone
0030=0.3 μm HSC=226 /Flat (PBT Insert) 10=10″ E=EPDM
0050=0.5 μm HTF=222 /Fin (PBT Insert) 20=20″ V=Viton
  HTC=222 /Flat (PBT Insert) 30=30″  
  DOE=Double Open End 40=40″  

Downloads

Hall Pyke GlassGas

File name: Hall-Pyke-GlassGas.pdf
File size: 1.4MB

  • Pages

    • All Downloads
      • Company Downloads
      • Hall Pyke Publications
      • How-Tos
    • Contact Us
    • Cookie Policy
    • Customer Support
    • Download locked
    • Gallery
    • Lab Support Services
      • Filter Integrity Test
      • Filter Validation
      • Filterability Testing
      • Leak Detection Test for Baghouses
    • News
    • Our Product Range
    • Privacy & Cookie Policy
    • Request a Callback
    • Request a Quote
    • Support Videos
    • The SMART Choice for Filtration
    • Vacancies
    • Why Us
  • Archives

    • July 2025
    • December 2024
    • March 2022
    • December 2021
    • November 2021
    • October 2021
    • September 2021
  • Categories

    • News (2)
    • Uncategorized (8)

Get in Touch!

Hall Pyke

The SMART choice for filtration

T: +353-1-4501411
E: info@hallpyke.ie

Contact Us
Terms & Conditions
Cookie Policy
Privacy Policy

Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}