Hall Pyke

The SMART choice for filtration

  • Home
  • Products
    • Col 1
      • Backwashing and self-cleaning filters
      • Capsule Filtration
      • Compressed Air Filters
      • Depth Pre Filtration
      • Dust Filter Cartridges
      • Technical Fabric Filters
    • Col 2
      • Filter Housings
      • High Flow
      • HVAC
      • Hygienic Strainers
      • Liquid Bag Filtration
      • Membrane Filtration
    • Col 3
      • Stainless Steel Filters
      • Stainless Steel Mesh Fabrication
      • Steam Filtration
      • Surface Pre Filtration
      • Water Treatment
  • Services
    • Lab Support Services
    • Filter Integrity Test
    • Filterability Testing
    • Filter Validation
    • Customer Support
    • Leak Detection Test for Baghouses
  • Downloads
    • Hall Pyke Publications
    • Company Downloads
    • How-Tos
  • News
  • Why Us
  • Gallery
  • Contact Us
Home / Products / Membrane Filtration / High Flow Teflogas Vent Autoclave Filter Cartridges

High Flow Teflogas Vent Autoclave Filter Cartridges

High Flow Teflogas Vent Autoclave Filter Cartridges

Hydrophobic PTFE Membrane Sterilizing Grade

Cobetter High Flow Teflogas Vent Autoclave Filter Cartridges designed for critical applications where sterile air is required to break the vacuum formed by steam condensation inside the autoclave chamber, The filter cartridge consists of an inherently hydrophobic PTFE membrane and removing all particles down to 0,01 micron ensuring the removal of microorganisms including bacteria and viruses.

Cobetter High Flow Teflogas Vent Autoclave Filter Cartridges have been completely validated using the Bacterial Challenge Test and Aerosol Challenge Test respectively, Using Pseudomonas diminuta in the Bacterial Challenge Test, results in total bacterial retention, Using T1 bacteriophage (0,05 micron × 0.1 micron), in the Aerosol Challenge Test, allows removal to a gas micron rating of 0.01 micron. This ensures bacteria and bacteriophage removal especially during the vacuum-break period.

Categories / Industries:
Membrane Filtration, Products


Details

Email Us Call Us
  • Description
  • Downloads

Description

Specification

Filter Medium
Hydrophobic PTFE

Gage/Core
Boiypropylene

Gasket
EPDM/Silicone/Viton

End Caps
1/2″ BSPP, Male Thread

Effective Filter Area
90DHV-GPFL 0.01 1216 cm2
DHV-GPFL 0.01 2831 cm2

Max. Temperature
70°C

Max. Differential Pressure
4.5 bar/ 8090

Features and Benefits

  • High Flow Rates
  • Inherently Hydrophobic
  • Exceptional Mechanical Strength
  • Steam Sterilized Repeatedly at 140°C in an Autoclave
  • 100% Integrity Tested
  • Manufactured under a Quality Management System Certified to IS09001:2000

Material Safety

Meet the requirements for food contact in European
Regulation (EC) Number 1935/2004
Meet UPS <88> for Class VI-121°C Plastics

Dimensions

Available in 2 sizes to meet different requirements depending on the type of vacuum, autoclave size, maximum vacuum-break time required, or additional restrictions.

90DHV-GPFL-0020-E-P DHV-GPFL-0020-E-p
Length 90±1 mm 163±1 mm
Diameter 63±0,5 mm 63±0.5 mm
Surface Area 1216 cm2 2831 cm2

Ordering Information

Cat, No, Filter Medium Removal Ratings Seal Material
gODHV
DHV
PTFE
Glass microfiber
0,01
0,2
Slicone
EPOM
Viton

Downloads

High Flow Teflogas

File name: High-Flow-Teflogas.pdf
File size: 608.1KB

  • Pages

    • All Downloads
      • Company Downloads
      • Hall Pyke Publications
      • How-Tos
    • Contact Us
    • Cookie Policy
    • Customer Support
    • Download locked
    • Gallery
    • Lab Support Services
      • Filter Integrity Test
      • Filter Validation
      • Filterability Testing
      • Leak Detection Test for Baghouses
    • News
    • Our Product Range
    • Privacy & Cookie Policy
    • Request a Callback
    • Request a Quote
    • Support Videos
    • The SMART Choice for Filtration
    • Vacancies
    • Why Us
  • Archives

    • July 2025
    • December 2024
    • March 2022
    • December 2021
    • November 2021
    • October 2021
    • September 2021
  • Categories

    • News (2)
    • Uncategorized (8)

Get in Touch!

Hall Pyke

The SMART choice for filtration

T: +353-1-4501411
E: info@hallpyke.ie

Contact Us
Terms & Conditions
Cookie Policy
Privacy Policy

Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}