Hall Pyke

The SMART choice for filtration

  • Home
  • Products
    • Col 1
      • Backwashing and self-cleaning filters
      • Capsule Filtration
      • Compressed Air Filters
      • Depth Pre Filtration
      • Dust Filter Cartridges
      • Technical Fabric Filters
    • Col 2
      • Filter Housings
      • High Flow
      • HVAC
      • Hygienic Strainers
      • Liquid Bag Filtration
      • Membrane Filtration
    • Col 3
      • Stainless Steel Filters
      • Stainless Steel Mesh Fabrication
      • Steam Filtration
      • Surface Pre Filtration
      • Water Treatment
  • Services
    • Lab Support Services
    • Filter Integrity Test
    • Filterability Testing
    • Filter Validation
    • Customer Support
    • Leak Detection Test for Baghouses
  • Downloads
    • Hall Pyke Publications
    • Company Downloads
    • How-Tos
  • News
  • Why Us
  • Gallery
  • Contact Us
Home / Products / Membrane Filtration / APTF

APTF

APTF

Hall Pyke APTF-T Filter Cartridges are composed of an expanded hydrophobic PTFE membrane, ECTFE support and PVDF cage and core making it suitable to use in strong acid and solvent filtration. APTFI-T Filter Cartridges are composed of a hydrophilic PTFE membrane which is specially designed for aggressive water-based filtration conditions.

Features and Benefits

  • 100% all Fluoropolymer construction
  • Absolute rated in all ratings except 0.22μm; 0.22μm rating’s retention efficiency is up to 99.99999%
  • High filtration performance including high flow rates and low pressure drops
  • Available in both hydrophobic and hydrophilic PTFE media

Quality Standards

  • Each filter is individually Integrity Tested prior to leaving the factory
  • Each filter is Fully Traceable with a unique serial number
  • Designed, developed and manufactured in compliance with ISO9001
  • Full Regulatory Compliance with the following:
    • 21CFR.210.3(b)(5)(6), 211.72 for Non-Fiber Release
    • Endotoxins: <0.25EU/ml/10inch filter
    • USP <88> Plastic Class VI-121°C
    • FDA 21 CFR177-182 & EU 1935/2004/EC

Typical Applications

  • Strong Acid Filtration
  • Aggressive Solvents Filtration
Categories / Industries:
Membrane Filtration, Products


Details

Email Us Call Us
  • Description
  • Downloads

Description

Materials of Construction

Filter Media APTF-T/APTF: Expanded Hydrophobic PTFE Membrane
APTFI-T/APTFI: Expanded Hydrophilic PTFE Membrane
Cage/Core/End Caps PVDF
O-ring PTFE/PTFE Encapsulated Viton

Operating Conditions

Max. Continuous Operating Temperature 96°C
Max. Differential Pressure 5.0 bar / 21°C (forward)
3.0 bar / 80°C (forward)
Integrity Test Standards: APTF-T, 0.22μm BP: ≥ 0.1MPa (60%/40%, IPA/Water)
DF: ≤28ml/min/10”@80Kpa((60%/40%, IPA/Water
WIT: 0.53ml/min/10”@0/25MPa
Integrity Test Standards: APTFI-T, 0.22μm BP: ≥ 0.32MPa (Water)
BP: ≥ 0.1MPa (60%/40%, IPA/Water)
DF: ≤ 28ml/min/10”@80Kpa((60%/40%, IPA/Water)
Effective Filtration Area 0.96m2 / _ 68-10 inch

* Not Recommended for Inline Steam Sterilization and Autoclaving

Ordering Information

Removal Ratings End Cap Nominal Length Seal Material
0022 = 0.22_m SF=226 /Fin 05 = 5″ K=PTFE
0045 = 0.45_m SC=226 /Flat 10 = 10″ P=PTFE
0300 = 3.0_m DTF=D222 /Fin 20 = 20″ Encapsulated Viton
0500 = 5.0μm DTC=D222 /Flat 30 = 30″
DOE=Double Open End 40 = 40″

Downloads

Hall Pyke APTF

File name: Hall-Pyke-APTF.pdf
File size: 1MB

  • Pages

    • All Downloads
      • Company Downloads
      • Hall Pyke Publications
      • How-Tos
    • Contact Us
    • Cookie Policy
    • Customer Support
    • Download locked
    • Gallery
    • Lab Support Services
      • Filter Integrity Test
      • Filter Validation
      • Filterability Testing
      • Leak Detection Test for Baghouses
    • News
    • Our Product Range
    • Privacy & Cookie Policy
    • Request a Callback
    • Request a Quote
    • Support Videos
    • The SMART Choice for Filtration
    • Vacancies
    • Why Us
  • Archives

    • July 2025
    • December 2024
    • March 2022
    • December 2021
    • November 2021
    • October 2021
    • September 2021
  • Categories

    • News (2)
    • Uncategorized (8)

Get in Touch!

Hall Pyke

The SMART choice for filtration

T: +353-1-4501411
E: info@hallpyke.ie

Contact Us
Terms & Conditions
Cookie Policy
Privacy Policy

Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}