DN66T

DN66T® Filter Cartridges

Nylon 66 Membrane  ·  Sterile Liquid Filter

DN66T® Filter Cartridges are composed of an inherently hydrophilic Nylon 66 membrane. It’s specifically designed for bio-burden reduction and the final filtration of a wide range of pharmaceutical and biological solutions. A modified Nylon 66 membrane with positive-charged Zeta particles is available, which provides enhanced retention of fine particles such as endotoxins.

Features and Benefits

  • Intrinsically water wettability
  • Modified DN66T filter removes endotoxins through the formation of positive-charged Zeta particles
  • A more reliable retention efficiency is ensured by high bubble point testing
  • Low pressure drops and high flow rates
  • Longer service life

Quality Standards

Integrity Test correlates to ASTM F838-05 Bacterial Challenge Test (BCT)

  • Each filter is individually Integrity Tested prior to leaving the factory
  • Each filter is Fully Traceable with a unique serial number
  • Designed, developed and manufactured in compliance with 1809001
    • Full Regulatory Compliance with the following:
    • 21 CFR.21 0.3(b)(5)(6), 211 .72 for Non-Fiber Release
    • Endotoxins: <0.25EU/ ml/1 Oinch filter
    • USP <88> Plastic Class Vl-121 oc
    • FDA 21 CFR177 -182 & EU 1935/2004/EC

Typical Application

  • Buffer Solutions
  • WFI
  • LVP & Antibiotics

Flow Rate Characteristics

Materials of Construction

Filter Media Hydrophilic Nylon 66 Membrane
Support PET
Cage/Core/End Caps Polypropylene

Operating Conditions

Max. Temperature 80°C
Max. Differential Pressure 4.0 bar / 21°C (forward)

2.4 bar / 80°C (forward)

Effective Filtration Area 0.58m21 <Ω

68-10 inch

Sterilization

lnline Steam Sterilization up to 10 cycles (121°C for 30min@30kPa per cycle)

Integrity Test Data

Bubble Point BP : ≥ 0.38 MPa (water), 0.1 μm +0.1 μm
BP : ≥ 0.34 MPa (water), 0.22 μm +0.22 μm
BP : ≥ 0.30 MPa (water), 0.45 μm +0.22 μm

Ordering Information

Removal Rating End Cap Nominal Length Seal Material
1010 = 0.1 + 0.11μm HSF = 226 /Fin (PBT Insert) 05 = 5″ S = Silicone
2222 = 0 22 + 0 221μm HSC = 226 /Flat (PBT Insert) 0 = 10 E = EPDM
4545 = 0.45 + 0.451μm HTF = 222 /Fin (PBT Insert) 20 = 20″ V = Viton
1045 = 1.0 + 0.451μm HTC = 222 /Flat (PBT Insert) 30 = 30″
DOE = Double Open End 40 = 40″

 

Downloads

File Description File size Downloads
pdf Hall Pyke DN66T 2 MB 744