Product Attributes
Gaskets and O-Rings
Ethylene Propylene, PTFE encapsulated, Silicone or Nitrile.
Maximum Differential Pressure
| Normal flow direction at: | 
| 20°C (68°F): | 
6.0 bar (87lb/in2) | 
| 80°C (176°F): | 
4.0bar (58lb/in2) | 
| 100°C (212°F): | 
3.0 bar (43lb/in2) | 
| 120°C (248°F): | 
2.0 bar (29lb/in2) | 
| 125°C (257°F): | 
1.5bar (22lb/in2) | 
| Reverse flow direction at: | 
| 20°C (68°F): | 
2.1bar (30lb/in2) | 
| 80°C (176°F): | 
1.0bar (15lb/in2) | 
| 100°C (212°F): | 
0.5bar (7lb/in2) | 
Operating Temperature
Maximum continuous: 80°C (176°F).
Sterilisation
In situ steam 100 x 20 minute cycles at 135°C (275°F) to 150 x 20 minute cycles at 125°C (257°F).
Effective Filtration Area
| Absolute Microbial Rating | 
Effective Filtration Area (each 254mm (10″) module) | 
| 0.2μm | 
0.8m2 (8.6ft2) | 
Applications
- Sterile process gases
The supply of sterile gas for critical applications in the pharmaceutical, biotechnology, food and beverage markets. 
- Sterile vents
The safe sterile venting of processing vessels in pharmaceutical, fermentation, and food and beverage processes. 
- Biotechnology
The sterile filtration of exhaust gases from biological fermenters. 
- Powder handling and tabletting
The removal of ultrafine powder particles from compounding environments. 
Gas Flow Rates