Fluorofil™ Plus

High Flow Sterile Gas Filter with ePTFE Membrane

Fluorofil™ Plus cartridges are manufactured using a highly hydrophobic ePTFE membrane. The enhanced ePTFE membrane offers exceptionally high gas flow rates at low pressure differentials (see graph). Fluorofil™ Plus cartridges are recommended for sterile gas filtration and venting applications. The hydrophobic characteristics of the ePTFE membrane makes the Fluorofil™ Plus filter cartridge particularly suitable for wet gas sterilising applications, such as fermenter air feed.

Features and Benefits

  • Guaranteed microbial ratings in a liquid challenge
    Fluorofil™ Plus cartridges are validated for bacterial removal according to
    HIMA guidelines and ASTM F838-05, with a log reduction value >7.
  • High Flow ΔP characteristics
    The unique characteristics of the ePTFE membrane, having higher surface area, combined with the construction of the Fluorofil™ Plus filter cartridge, results in exceptionally high gas flow rates at low pressure differentials. These features result in lower energy consumption and fewer filter cartridges per system.
  • Mechanical strength
    Fluorofil™ Plus cartridges incorporate a stainless steel central core which provides greater mechanical strength. This allows the filter to be used at higher gas flow rates with low pressure differentials.
  • Cartridge integrity and low TOC levels
    All Fluorofil™ Plus cartridges are integrity tested and supplied clean, having been flushed with pure water.

Materials of Manufacture

Filter membrane: ePTFE
Membrane support: Polypropylene
Irrigation mesh (support): Polypropylene
Drainage layer: Polypropylene
Inner core: 316L Stainless Steel
Outer support: Polypropylene
End fittings: Polypropylene
Sealing: Fusion bonding

Downloads

File Description File size Downloads
pdf Fluorofil_Plus-Hall 301 KB 874

Product Attributes

Gaskets and O-Rings

Ethylene Propylene, PTFE encapsulated, Silicone or Nitrile.

Maximum Differential Pressure

Normal flow direction at:
20°C (68°F): 6.0 bar (87lb/in2)
80°C (176°F): 4.0bar (58lb/in2)
100°C (212°F): 3.0 bar (43lb/in2)
120°C (248°F): 2.0 bar (29lb/in2)
125°C (257°F): 1.5bar (22lb/in2)
Reverse flow direction at:
20°C (68°F): 2.1bar (30lb/in2)
80°C (176°F): 1.0bar (15lb/in2)
100°C (212°F): 0.5bar (7lb/in2)

Operating Temperature

Maximum continuous: 80°C (176°F).

Sterilisation

In situ steam 100 x 20 minute cycles at 135°C (275°F) to 150 x 20 minute cycles at 125°C (257°F).

Effective Filtration Area

Absolute Microbial Rating Effective Filtration Area (each 254mm (10″) module)
0.2μm 0.8m2 (8.6ft2)

Applications

  • Sterile process gases
    The supply of sterile gas for critical applications in the pharmaceutical, biotechnology, food and beverage markets.
  • Sterile vents
    The safe sterile venting of processing vessels in pharmaceutical, fermentation, and food and beverage processes.
  • Biotechnology
    The sterile filtration of exhaust gases from biological fermenters.
  • Powder handling and tabletting
    The removal of ultrafine powder particles from compounding environments.

Gas Flow Rates

Photo