HFC Disconnect Series Connectors

HFC Disconnects enable sterile disconnection of single- use biopharma and cell and gene therapy manufacturing systems. With an easy push of the connector thumb latch, sterility is maintained on both sides of the system during the disconnection process. The HFC Disconnect sets include protective thumb latch covers to help reduce the chance of accidental disconnection, and are laser marked with item and lot number for complete batch traceability.

Category:
Features Benefits
Intuitive one-step disconnection process Minimize operation error and eases standard operation procedure creation and training
Ease of connectivity No requirement for additional equipment to make sterile disconnection
Audible “click” Provides confidence of a secure connection
Protective thumb latch cover Eliminate accidental disconnects
Laser etched item number and lot number Full traceability to raw material source
Alloy C-276 internal flow path spring Enabling broader application compatibility

Downloads

File Description File size Downloads
pdf CPC-HFC-Disconnect-Spec-Sheet 268 KB 155

Product Attributes

Specifications & CV Value

Operating Conditions (Fluid Transfer)

Pressure: Up to 75 psi, 5.17 bar
Temperature: 34°F (1°C) to 104°F (40°C)

Materials

Main components: Polysulfone (amber tint), USP Class VI, ADCF
O-rings: Silicone (clear), platinum-cured, USP Class VI, ADCF
Flow Path Springs: Alloy C-276

Sterilization

Gamma: Up to 50 kGy irradiation.Sterilize coupled or uncoupled.
Autoclave: Up to 270°F (132°C) for 60 minutes. One cycle

Cv Value

HFC Disconnect 1/4” CV Value 0.77
HFC Disconnect 3/8” CV Value 1.1
HFC Disconnect 1/2” CV Value 1.9
Cv values are based on gpm and psi, and Ipm and bar (shown in parentheses).