SteriPS

SteriPS Filter Cartridges

PES Membrane  ·  Sterile Liquid Filter

SteriPS Filter Cartridges are specially designed to provide a reliable sterilizing solution at an economical cost. Hydrophilic PES membrane cartridges require no pre-wetting and are ready to use. In addition, these filters provide excellent performance in pharmaceutical applications.

Features and Benefits

  • Low diffusion flow
  • Inherently hydrophilic PES membrane
  • High surface area provides excellent flow rates and extended service life while maintaining high bacteria removal efficiency
  • Low protein binding

Quality Standards

  • Integrity Test correlates to ASTM F838-05 Bacterial Challenge Test (BCT)
  • Each filter is individually Integrity Tested prior to leaving the factory
  • Each filter is Fully Traceable with a unique serial number
  • Designed, developed and manufactured in compliance with ISO9001
  • Full Regulatory Compliance with the following:
    • 21CFR.210.3(b)(5)(6), 211.72 for Non-Fiber Release
    • Endotoxins: <0.25EU/ml/10inch filter
    • USP <88> Plastic Class VI-121°C
    • FDA 21 CFR177-182 & EU 1935/2004/EC

Typical Applications

  • Antibiotics
  • LVP & SVP
  • Large Batch Solutions
  • Cleaning & Disinfecting Liquids

Flow Rate Characteristics

Materials of Construction

Filter Media PES Membrane
Cage/Support Polypropylene
Core/End Caps Polypropylene

Operating Conditions

Maximum Temperature 90°C
Max.Differential Pressure 4.0bar / 21°C (forward)
  2.4bar / 90°C (forward)
Effective Filtration Area 0.58m2/ μ 68-10 inch

Sterilization

Inline Steam Sterilization up to 30 cycles (135°C for 30min@30kPa per cycle)
Autoclave up to 30 cycles (130°C for 30min per cycle)

Integrity Test Data

Bubble Point BP : ≥ 0.32 MPa (water), 0.22 μm
  BP : ≥ 0.20 MPa(water), 0.45 μm
Diffusion Flow DF : ≤ 25 ml/min/10”@ 0.275 Mpa, 0.22 μm
  DF : ≤ 25 ml/min/10”@ 0.15 Mpa, 0.45 μm

Ordering Information

Removal Ratings End Cap Nominal Length Seal Material
0010=0.1μm HSF=226 /Fin (PBT Insert) 05=5″ S =Silicone
0022=0.22μm HSC=226 /Flat (PBT Insert) 10=10″ E =EPDM
0045=0.45μm HTF=222 /Fin (PBT Insert) 20=20” V =Viton
  HTC=222 /Flat (PBT Insert) 30=30”  
  DOE=Double Open End 40=40”  

Downloads

File Description File size Downloads
pdf Hall Pyke SteriPS 1 MB 774