Hall Pyke

The SMART choice for filtration

  • Home
  • Products
    • Col 1
      • Backwashing and self-cleaning filters
      • Capsule Filtration
      • Compressed Air Filters
      • Depth Pre Filtration
      • Dust Filter Cartridges
      • Technical Fabric Filters
    • Col 2
      • Filter Housings
      • High Flow
      • HVAC
      • Hygienic Strainers
      • Liquid Bag Filtration
      • Membrane Filtration
    • Col 3
      • Stainless Steel Filters
      • Stainless Steel Mesh Fabrication
      • Steam Filtration
      • Surface Pre Filtration
      • Water Treatment
  • Services
    • Lab Support Services
    • Filter Integrity Test
    • Filterability Testing
    • Filter Validation
    • Customer Support
    • Leak Detection Test for Baghouses
  • Downloads
    • Hall Pyke Publications
    • Company Downloads
    • How-Tos
  • News
  • Why Us
  • Gallery
  • Contact Us
Home / Products / Membrane Filtration / TefloGas

TefloGas

TefloGas

TefloGas Filter Cartridges

Hydrophobic PTFE Membrane  ·  Sterile Gas Filter

TefloGas Filter Cartridges are composed of a hydrophobic PTFE membrane and a thick thermal-resistance polypropylene core. They are characterized by a high filtration area and non-metallic ion release and are easy to clean when compared to filters with a stainless steel core. As a result, they are highly recommended for air and gas sterile filtration of biological liquids and fermentation and pharmaceutical industries.

Features and Benefits

  • Inherently hydrophobic
  • Exceptionally high flow rates with low pressure drops

Quality Standards

  • Integrity Test correlates to ASTM F838-05 Bacterial Challenge Test (BCT)
  • Each filter is individually Integrity Tested (including Water Intrusion Test) prior to leaving the factory
  • Each filter is Fully Traceable with a unique serial number
  • Designed, developed and manufactured in compliance with ISO9001
  • Full Regulatory Compliance with the following:
    • 21CFR.210.3(b)(5)(6), 211.72 for Non-Fiber Release
    • Endotoxins: <0.25EU/ml/10inch filter
    • USP <88> Plastic Class VI-121°C
    • FDA 21 CFR177-182 & EU 1935/2004/EC

Typical Applications

  • Aseptic Packaging
  • Compressed Air and Nitrogen Gas Sterilization
  • Corrosive Gases Sterilization
  • Vent Filtration
Categories / Industries:
Membrane Filtration, Products


Details

Email Us Call Us
  • Description
  • Downloads

Description

Flow Rate Characteristics

Materials of Construction

Filter Media Hydrophobic PTFE Membrane
Support Polypropylene
Core/Cage/End Caps Polypropylene

 Operating Conditions

Maximum Temperature 80°C
Max. Differential Pressure 5.0 bar / 21°C (forward)
  2.4 bar / 80°C (forward)
Effective Filtration Area 0.75m2/ μ 69-10 inch

Sterilization

In-line Steam Sterilization up to 100 forward cycles (145°C for 30min at 30kPa for every cycle)
Autoclave up to 400 cycles (130°C for 30min for every cycle)

Integrity Test Data

Bubble Point BP : ≥0.11Mpa (60%/40%IPA/Water), 0.01μm
Diffusion Flow DF : ≤16ml/min/10”cartridge@80KPa(60%/40%IPA/Water), 0.01μm
Water Intrusion Test WFT : ≤0.38ml/min/10”cartridge@0.25MPa,0.01μm

Ordering Information

Removal Ratings End Cap Nominal Length Seal Material
0001=0.01μm HSF=226 /Fin (PBT Insert) 05=5″ S =Silicone
0022=0.22μm HSC=226 /Flat (PBT Insert) 10=10″ E =EPDM
  HTF=222 /Fin (PBT Insert) 20=20” V =Viton
  HTC=222 /Flat (PBT Insert) 30=30” P=FEP Encapsulated Viton
  DOE=Double Open End 40=40”  

Downloads

Hall Pyke TefloGas

File name: Hall-Pyke-TefloGas.pdf
File size: 2.6MB

  • Pages

    • All Downloads
      • Company Downloads
      • Hall Pyke Publications
      • How-Tos
    • Contact Us
    • Cookie Policy
    • Customer Support
    • Download locked
    • Gallery
    • Lab Support Services
      • Filter Integrity Test
      • Filter Validation
      • Filterability Testing
      • Leak Detection Test for Baghouses
    • News
    • Our Product Range
    • Privacy & Cookie Policy
    • Request a Callback
    • Request a Quote
    • Support Videos
    • The SMART Choice for Filtration
    • Vacancies
    • Why Us
  • Archives

    • July 2025
    • December 2024
    • March 2022
    • December 2021
    • November 2021
    • October 2021
    • September 2021
  • Categories

    • News (2)
    • Uncategorized (8)

Get in Touch!

Hall Pyke

The SMART choice for filtration

T: +353-1-4501411
E: info@hallpyke.ie

Contact Us
Terms & Conditions
Cookie Policy
Privacy Policy

Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}